Configmgr SP1 CU2 upgrade : smsPXE.log reporting “Failed to get information for MP: http://sccm.test01.BE. 80090006”

June 21, 2013 at 12:25 pm in Uncategorized by Kenny Buntinx [MVP]

 

CU2 for Configmgr 2012 SP1 is just released and we already faced a minor issue.

Today we implemented CU2 in production on our Configmgr 2012 SP1 platform . After the upgrade we couldn’t stage anymore .After verifying the smspxe.log , it showed us this error :

image

Solution:

Update your bootimages on the distibution points and the log will turn back healthy again . We suspect it has something to do with the Cumulative Update 2 that offers limited support for deployment of Windows PE 3.1-based images. These images need to be finalized before adding to the site server. If later changes are needed, they can be made using DISM.

image

Hope it Helps ,

Kenny Buntinx

Enterprise Client Management MVP